Does anyone know the proper braking resistor ohmic value and wattage for a TECO FM100-202? This is a 2 HP rated drive to which I have connected a 1 HP motor.

W

wrench

Titanium
Joined
Jul 9, 2002
Location
Sunnyvale, CA
  • Jun 9, 2004
  • #2

I don't have an explicit answer for you, but often those smaller VFDs (especially the new ones) have built-in resistors. Your unit is pretty small, so I'd check out the documentation to make sure that isn't the case for you.

Alan

Forrest Addy

Diamond
Joined
Dec 20, 2000
Location
Bremerton WA USA
  • Jun 9, 2004
  • #3

I don't know about your VFD but my book on the 2 HP rated Magnetek GPD 333 lists 100 ohms 200 Watt resistor for a DB resistor. If your application involves stops of high inertia loads from high RPM better get a 500 Watt.

I have a total of 100 watts DB resistor on the VFD of my 10 HP lathe. Two stops from 2000 RPM's in rapid succession with the 10" three jaw get the resistor hot enough to sizzle spit (No biggie, it's ceramic and is safe to almost red heat).

[This message has been edited by Forrest Addy (edited 06-09-2004).]

J

J Lauffer

Hot Rolled
Joined
Feb 9, 2004
Location
Attleboro, MA, USA
  • Jun 9, 2004
  • #4

Phil, as wrench indicated, many small VFDs have a certain amount of dynamic nraking built-in, and then if you need more you can add a resistor. If you indeed need to add a resistor, Forrest's numbers sound about right.

S

sch

Hot Rolled
Joined
Feb 11, 2004
Location
Bham, AL
  • Jun 9, 2004
  • #5

www.dealerselectric.com/FM100.html
has a link to "accessories" which includes
a TECO braking resistor for ~$24 or so
depending. Probable digikey or mouser
price would not be a lot different as
once you go above 100watts, resistors
get pricey. No actual specs on ohms/watts
on the dealerselectric site though. Steve

Forrest Addy

Diamond
Joined
Dec 20, 2000
Location
Bremerton WA USA
  • Jun 10, 2004
  • #6

People adding a DB resistor should shop around before they buy the factory part. The Magnetek (now Yaskawa) DB resistor for a 5 HP GDP 333 lists for $300. The same rated resistor from Newark Electronics is $16. Go figure.

For $286 I can build a little vented enclosure.

[This message has been edited by Forrest Addy (edited 06-09-2004).]

motion guru

Diamond
Joined
Dec 8, 2003
Location
Yacolt, WA
  • Jun 11, 2004
  • #7

Also, the replacement strip heaters in McMaster Carr make great dynamic braking resistors. You have to calculate the resistance based on the specs printed in the catalog.

B

brent

Joined
Dec 18, 2004
Location
Saskatchewan Canada
  • Jun 12, 2004
  • #8

your owners manual lists the specs for the resistor. a while back some one (I think Forrest) posted a page from newark showing a resistor--- I bought one and put on my Teco fm-100 on my mill works great.
brent

C

Chris Attebery

Cast Iron
Joined
Jun 14, 2002
Location
Gilroy, CA, USA
  • Jun 14, 2004
  • #9

I took a trip to the local surplus electronics shop. I found a 40ohm 250W unit for less than $10 out the door. Should be plenty for my little 1hp mill if Forrest can get away with 200w on his 10hp lathe.

Chris

J

J Lauffer

Hot Rolled
Joined
Feb 9, 2004
Location
Attleboro, MA, USA
  • Jun 14, 2004
  • #10

Chris, sounds like a great deal, but 40 ohms may be too low for a 1 Hp drive. The lower the ohms, the more current will be drawn by the resistor. The DB chopper circuit, especially if it is built-in to the VFD, may not be able to handle it. This could lead to damage of the DB circuit, or the drive may trip anytime the DB tries to turn on.

Typical ohm values for 1 Hp VFDs are usually in the 100-150 ohm range. 40 ohms is more in line for a 5 Hp VFD. If the VFD uses the same DB circuit for a 1 Hp as it does for a 5 Hp then you would be OK. I would ask the VFD manufacturer what their recommended ohms and watts ratings are.

C

Chris Attebery

Cast Iron
Joined
Jun 14, 2002
Location
Gilroy, CA, USA
  • Jun 14, 2004
  • #11

Hey Jim,

Thanks for the input. This is for a Baldor BDI 1100 drive. According to the manual it needs a resistor with a resistance of 30 ohms or more. No other specs of course.

Once I get it I'll play with the braking function. Not sure I really need it, but it would be nice to not have to brake manually. I guess if it trips on braking I'll know why in advance. They had a few different sizes in stock. I could always swap it.

BTW: The braking resistor only switches in if the bus voltage goes over 375ish on a 240v drive right? So a 40ohm resistor across a 375v drop will pull 9.375 amps? Doesn't sound too bad. 3.5 kw peak? That should smell nice. :^)

Thanks,

Chris

You must log in or register to reply here.

VFD braking resistor (2024)

References

Top Articles
Latest Posts
Article information

Author: Greg O'Connell

Last Updated:

Views: 6073

Rating: 4.1 / 5 (62 voted)

Reviews: 85% of readers found this page helpful

Author information

Name: Greg O'Connell

Birthday: 1992-01-10

Address: Suite 517 2436 Jefferey Pass, Shanitaside, UT 27519

Phone: +2614651609714

Job: Education Developer

Hobby: Cooking, Gambling, Pottery, Shooting, Baseball, Singing, Snowboarding

Introduction: My name is Greg O'Connell, I am a delightful, colorful, talented, kind, lively, modern, tender person who loves writing and wants to share my knowledge and understanding with you.